A 2-pole, single-phase alternator driven at 3000rpm require a mechanical input to its rotor of 30kW when it is delivering its full-load output of 30kW. Under this condition the fixed and variable losses are1100W and 2.8kW respectively, and the rotor field winding is supplied from a 110V dc source. Given that the full-load efficiency is 87%, determine. 1. the frequency generated, 2. the input driving torque on full-load and 3. the rotor field current IF

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
nsert
1
A Arial
Draw
Uab x, x² Po
Font
8
Design
- 11 ✔
A Aa A A
11.1
π-e² -∞0-=
Layout
References
- 2 T
Paragraph
√
2 13 14 15 16 1
Document1 W...
Mailings Review View
A
Styles
Styles
Editing Dictate
IF
0
1. the frequency generated,
2. the input driving torque on full-load and
3. the rotor field current
Help
M Kingy
Voice
7
12 13 1
I
8 9 10 11
Sensitivity Editor
Add-ins
Sensitivity Editor Add-ins
14 15 1
A 2-pole, single-phase alternator driven at 3000rpm require a mechanical input
to its rotor of 30kW when it is delivering its full-load output of 30kW. Under this
condition the fixed and variable losses are1100W and 2.8kW respectively, and
the rotor field winding is supplied from a 110V dc source. Given that the full-load
efficiency is 87%, determine.
^
17
Transcribed Image Text:nsert 1 A Arial Draw Uab x, x² Po Font 8 Design - 11 ✔ A Aa A A 11.1 π-e² -∞0-= Layout References - 2 T Paragraph √ 2 13 14 15 16 1 Document1 W... Mailings Review View A Styles Styles Editing Dictate IF 0 1. the frequency generated, 2. the input driving torque on full-load and 3. the rotor field current Help M Kingy Voice 7 12 13 1 I 8 9 10 11 Sensitivity Editor Add-ins Sensitivity Editor Add-ins 14 15 1 A 2-pole, single-phase alternator driven at 3000rpm require a mechanical input to its rotor of 30kW when it is delivering its full-load output of 30kW. Under this condition the fixed and variable losses are1100W and 2.8kW respectively, and the rotor field winding is supplied from a 110V dc source. Given that the full-load efficiency is 87%, determine. ^ 17
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps with 3 images

Blurred answer
Knowledge Booster
Synchronous Generator
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,