Five large hotels in Miami, USA, use their own air-conditioning units, which have a c.o.p. 3.1. It is proposed that the cooling systems of the five hotels be substituted with a larger, modern unit that would have a c.o.p. 3.7. The total installed capacity of the five hotels is 2,600 tons of air-conditioning and the current systems are in use for 3,200 hours every year. Determine: a) the annual energy savings from this substitution and b) the annual avoidance of CO₂ emissions if, currently, 72% of the electric energy in the Miami area is obtained from coal power plants and 28% from nuclear power plants.

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter44: Geothermal Heat Pumps
Section: Chapter Questions
Problem 12RQ: The function of the pressure tank in an open-loop, geo-thermal heat pump well system is to prevent...
icon
Related questions
Question
11. Five large hotels in Miami, USA, use their own air-conditioning units, which
have a c.o.p. 3.1. It is proposed that the cooling systems of the five hotels be
substituted with a larger, modern unit that would have a c.o.p. 3.7. The total
installed capacity of the five hotels is 2,600 tons of air-conditioning and the
current systems are in use for 3,200 hours every year. Determine: a) the annual
energy savings from this substitution and b) the annual avoidance of CO₂
emissions if, currently, 72% of the electric energy in the Miami area is
obtained from coal power plants and 28% from nuclear power plants.
Transcribed Image Text:11. Five large hotels in Miami, USA, use their own air-conditioning units, which have a c.o.p. 3.1. It is proposed that the cooling systems of the five hotels be substituted with a larger, modern unit that would have a c.o.p. 3.7. The total installed capacity of the five hotels is 2,600 tons of air-conditioning and the current systems are in use for 3,200 hours every year. Determine: a) the annual energy savings from this substitution and b) the annual avoidance of CO₂ emissions if, currently, 72% of the electric energy in the Miami area is obtained from coal power plants and 28% from nuclear power plants.
Expert Solution
steps

Step by step

Solved in 4 steps

Blurred answer
Knowledge Booster
Convection
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning