SOLARIA Power XT TM Panel Analysis An I-V set of curves and mechanical characteristics are given for a Solaria solar panel. 10 CURRENT (A) 9 8 05. 1 0 0 5 (c) (d) (e) this value. (f) 10 15 20 Mechanical Characteristics Cell Type Dimensions (L x W x H) Weight Glass Type / Thickness Frame Type Cable Type / Length Connector Type Junction Box Front Load (UL 1703) Rear Load (UL 1703) *Refer to Solaria Installation Manual for details 1000 W/m² 800 W/m² 600 W/m² 400 W/m² 200 W/m² 25 VOLTAGE (V) 30 35 40 Monocrystalline Silicon. 1621mm x 1116mm x 40mm 21 kg/46 lbs AR Coated, Tempered / 3.2mm Anodized Aluminum 12 AWG PV Wire (UL) / 1000mm Amphenol H4 (MC4 compatible) IP67/4 diodes 5400 Pa/ 113 psf* 2400 Pa/ 50 psf* 45 50 43.9 11161 Reasonable accepted/typical value for the solar constant above the Earth's atmosphere Reasonable accepted/typical value for the solar constant at the surface of the Earth Open Circuit Voltage, Voc using your Part (b) value Short Circuit Current, Isc using your Part (b) value Estimate of maximum Power Output and illustrate, on the graph, how you obtained Panel Conversion Efficiency

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question

No explanaiton needed

SOLARIA Power XT ™
Panel Analysis
An I-V set of curves and mechanical characteristics are given for a Solaria solar panel.
10
1000 W/m?
9
8
800 W/m?
7
600 W/m2
6
43.9
11161
400 W/m2
4
3
200 W/m?
2
1
10
15
20
25
30
35
40
45
50
VOLTAGE (V)
Mechanical Characteristics
Cell Type
Dimensions (L x W x H)
Weight
Glass Type / Thickness
Frame Type
Cable Type / Length
Connector Type
Monocrystalline Silicon
1621mm x 1116mm x 40mm
21 kg / 46 Ibs
AR Coated, Tempered / 3.2mm
Anodized Aluminum
12 AWG PV Wire (UL) / 1000mm
Amphenol H4 (MC4 compatible)
Junction Box
IP67 / 4 diodes
Front Load (UL 1703)
Rear Load (UL 1703)
5400 Pa / 113 psf*
2400 Pa / 50 psf*
*Refer to Solaria Installation Manual for details
Reasonable accepted/typical value for the solar constant above the Earth's atmosphere
Reasonable accepted/typical value for the solar constant at the surface of the Earth
Open Circuit Voltage, Voc using your Part (b) value
Short Circuit Current, Isc using your Part (b) value
Estimate of maximum Power Output and illustrate, on the graph, how you obtained
(а)
(b)
this value.
(f)
Panel Conversion Efficiency
Transcribed Image Text:SOLARIA Power XT ™ Panel Analysis An I-V set of curves and mechanical characteristics are given for a Solaria solar panel. 10 1000 W/m? 9 8 800 W/m? 7 600 W/m2 6 43.9 11161 400 W/m2 4 3 200 W/m? 2 1 10 15 20 25 30 35 40 45 50 VOLTAGE (V) Mechanical Characteristics Cell Type Dimensions (L x W x H) Weight Glass Type / Thickness Frame Type Cable Type / Length Connector Type Monocrystalline Silicon 1621mm x 1116mm x 40mm 21 kg / 46 Ibs AR Coated, Tempered / 3.2mm Anodized Aluminum 12 AWG PV Wire (UL) / 1000mm Amphenol H4 (MC4 compatible) Junction Box IP67 / 4 diodes Front Load (UL 1703) Rear Load (UL 1703) 5400 Pa / 113 psf* 2400 Pa / 50 psf* *Refer to Solaria Installation Manual for details Reasonable accepted/typical value for the solar constant above the Earth's atmosphere Reasonable accepted/typical value for the solar constant at the surface of the Earth Open Circuit Voltage, Voc using your Part (b) value Short Circuit Current, Isc using your Part (b) value Estimate of maximum Power Output and illustrate, on the graph, how you obtained (а) (b) this value. (f) Panel Conversion Efficiency
Expert Solution
steps

Step by step

Solved in 5 steps with 10 images

Blurred answer
Knowledge Booster
Basic Signals and Its Properties
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,